Planning Information  
Pro 24" (610) Deep Wall Ventilation Hood  
M O D E L P W 6 0 2 4 1 8 ( R )  
Hand finished  
craftsmanship  
Classic stainless  
steel finish  
Stainless steel  
baffle filters  
Decorative rail  
(optional)  
Model PW602418  
Location of  
rating plate  
Model PW602418R  
Rail Option  
Welded seams  
and hemmed edges  
Recessed easy-  
access controls  
Halogen lighting  
Infinite-speed  
blower control  
Model PW602418R shown with decorative rail.  
Wolf Pro wall hoods provide the ultimate in  
ventilation. With standard elements like heat sentry  
and dual setting halogen lighting, Wolf elevates the  
need for ventilation to an enjoyable perk.  
Wolf Pro 24" (610) deep wall hoods  
are available in the classic stainless steel  
finish. Rail option hoods (R) come with a  
classic stainless steel decorative rail and  
stand-offs. Optional platinum or brass  
rails match dual fuel range bezels. Pro  
wall hoods are sold as a shell only;  
internal, in-line and remote blower  
options are available.  
Pro 24" (610) deep wall hoods are available in the  
classic stainless steel finish. You also have the option  
of a decorative rail. While a classic stainless steel rail  
is standard on (R) models, platinum or brass rails are  
available to match the bezels of our dual fuel ranges  
and sealed burner rangetops.  
Pro wall ventilation hoods are recommended for use  
with all Wolf cooking appliances. For optimal perform-  
ance, a Pro 27" (686) deep wall hood is recommended  
for use with ranges and rangetops that contain a  
charbroiler or griddle.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
1
7/07  
 
Planning Information  
Pro 24" (610) Deep Wall Ventilation Hood  
M O D E L P W 6 0 2 4 1 8 ( R )  
B L O W E R O P T I O N S  
1200 CFM Internal Blower  
1100 CFM In-Line Blower  
1200 CFM Remote Blower  
1500 CFM Remote Blower  
S P E C I F I C A T I O N S  
810316  
808332  
801642  
804701  
Overall Width of Hood  
Overall Height of Hood  
60" (1524)  
18" (457)  
Overall Depth of Hood  
(including rail)  
24" (610)  
26" (660)  
Internal Blower Option  
In-Line Blower Option  
Remote Blower Options  
Discharge  
1200 CFM  
1100 CFM  
Refer to Pro Ventilation Recommendations  
at the end of this section.  
1200 or 1500 CFM  
Vertical or Horizontal*  
10" (254) Round  
A C C E S S O R I E S  
Platinum or brass decorative rail  
and stand-offs  
Duct Size  
Electrical Supply Requirements  
110/120 V AC, 60 Hz  
15 amp dedicated circuit  
38" (965) high classic stainless  
steel backsplash with or without  
warming racks  
Shipping Weight (shell only)  
135 lbs (61 kg)  
6" (152), 12" (305), 18" (457) and  
24" (610) classic stainless steel  
duct covers  
*Horizontal discharge applications require a horizontal discharge kit.  
Specifications are subject to change without notice.  
Horizontal discharge kit  
Accessories are available through your  
Wolf dealer. To obtain local dealer  
information, visit the Showroom Locator  
section of our website, wolfappliance.com.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
3
 
Planning Information  
Pro 24" (610) Deep Wall Ventilation Hood  
M O D E L P W 6 0 2 4 1 8 ( R )  
I N S T A L L A T I O N S P E C I F I C A T I O N S  
LOCATION OF  
6"  
E
ELECTRICAL (152)  
5"  
(127)  
18" (457)  
HEIGHT  
OF HOOD  
60" (1524)  
WIDTH OF HOOD  
(
)
30" TO 36"  
(762914)  
30" TO 36"  
(762914)  
24" 610  
DEPTH OF HOOD  
TO COUNTERTOP  
TO COUNTERTOP  
NOTE: 24" (610) deep wall hoods can be vertical or horizontal discharge.  
D I M E N S I O N S  
Overall Width of Hood  
60" (1524)  
18" (457)  
24" (610)  
Overall Height of Hood  
Overall Depth of Hood (excluding rail)  
Countertop to Bottom of Hood  
Location of Electrical  
30" (762) to 36" (914)  
Within shaded area  
See Installation Instructions shipped with unit for detailed specifications.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
4
 
Planning Information  
Pro 24" (610) Deep Wall Ventilation Hood  
M O D E L P W 6 0 2 4 1 8 ( R )  
I N S T A L L A T I O N N O T E S  
Refer to the illustrations and specifications  
IMPORTANT NOTE: Install this ventilation hood  
for overall dimensions and installation specifics.  
only with a Wolf blower.  
Wolf Pro wall ventilation hoods are recom-  
mended for use with any Wolf cooking appli-  
ance, and should be as least as wide as the  
cooking surface. It is recommended that the  
hood overlap the cooking surface by 3" (76) on  
either side.  
Pro wall hoods require a separate, grounded  
110/120 V AC, 60 Hz power supply. The service  
should have its own 15 amp circuit breaker.  
Placement of the electrical supply is not critical,  
as long as you provide enough 120 V AC, 60 Hz  
power cable to make the electrical connection.  
Locate electrical within the shaded area shown  
in the Installation illustration on page 4.  
IMPORTANT NOTE: For optimal performance, a  
Pro 27" (686) deep wall hood is recommended  
for use with ranges and rangetops that contain  
a charbroiler or griddle.  
You must follow all National Electrical Code  
regulations. In addition, be aware of local codes  
and ordinances when installing your service.  
Installation of all Pro ventilation hoods  
should be 30" (762) to 36" (914) from the  
bottom of the hood to the countertop. Follow  
the dimensions shown in the Installation  
illustration on page 4.  
Refer to the installation instructions shipped  
with each Wolf product for detailed specifica-  
tions. This information can also be found on  
our website, wolfappliance.com.  
Wolf Pro wall hoods are shipped without a  
blower assembly. Internal, in-line or remote  
blower assemblies are available. Blower options  
also vary with the volume of air that needs to  
be moved and the length of the duct run. Refer  
to the charts at the end of this section for Pro  
ventilation recommendations and blower  
options.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
5
 
Planning Information  
Pro 24" (610) Deep Wall Ventilation Hood  
M O D E L P W 6 0 2 4 1 8 ( R )  
D U C T I N G C O N S I D E R A T I O N S  
Wolf Pro 24" (610) deep wall hoods are shipped  
without the blower assembly. Internal, in-line  
and remote blower assemblies are available.  
Local building codes may require the use of  
make-up air. Consult your local HVAC profes-  
sional for specific requirements in your area.  
IMPORTANT NOTE: Install this ventilation hood  
only with a Wolf blower.  
IMPORTANT NOTE: Wolf Pro 24" (610) deep  
wall hoods must be vented to the outside. Use  
only metal ductwork.  
Pro 24" (610) deep wall hoods have a vertical  
discharge. A horizontal discharge kit is available  
as a sales accessory.  
Refer to the illustration below for ducting  
considerations for Pro 24" (610) deep wall  
hoods.  
The hood will operate most efficiently when  
ductwork does not exceed 50' (15 m) in length.  
Ducting for Pro 24" (610)  
deep wall hoods.  
DUCTWORK INSTALLATION  
THROUGH ROOF  
ROOF CAP OR REMOTE BLOWER  
10" (254) ROUND DUCT  
TRANSITION  
221/4"W x 9"D TO 10" ROUND  
10"H (INCLUDING FLANGES)  
SOFFIT OR CABINET  
OR DUCT COVER  
VERTICAL DISCHARGE  
18" (457)  
HEIGHT OF HOOD  
WALL HOOD  
24" (610)  
DEPTH OF HOOD  
30" TO 36"  
(762–914)  
COUNTERTOP  
TO BOTTOM OF  
VENTILATION HOOD  
36" (914)  
STANDARD  
FLOOR TO  
COUNTERTOP  
HEIGHT  
NOTE: HORIZONTAL DISCHARGE REQUIRES AN ACCESSORY KIT.  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
6
 
Planning Information  
Pro 24" (610) Deep Wall Ventilation Hood  
M O D E L P W 6 0 2 4 1 8 ( R )  
W O L F B L O W E R A S S E M B L I E S  
A ventilation system must include a blower  
assembly. Wolf ventilation hoods are shipped  
without the blower assembly. An internal, in-line  
or remote blower assembly must be selected to  
accommodate the cooking appliance, CFM  
requirements and homeowner preferences.  
Internal, in-line and remote blower assemblies  
are available as sales accessories through your  
Wolf dealer.  
Internal blowers are mounted inside the hood  
canopy. In-line blowers are mounted in between  
the hood and the exterior of the home. Remote  
blowers can be mounted on the roof or in some  
cases, on an exterior wall. Refer to the illustra-  
tions below for dimensions of Wolf in-line and  
remote blowers.  
Pro ventilation recommendation charts on the  
following page provide minimum CFM recom-  
mendations according to the cooking appliance  
and ventilation hood used and blower options  
for each specific Pro 24" (610) deep wall hood.  
IMPORTANT NOTE: Use only a Wolf blower  
with all Wolf ventilation products.  
7
24 /8"  
(632)  
3
24 /8"  
(619)  
3
18"  
11 /4"  
12"  
(457)  
(298)  
(305)  
1
18 /2"  
(470)  
1
4 /2"  
(114)  
8"  
(203)  
1
21 /2"  
22"  
18"  
1
(546)  
(559)  
12 /4"  
(311)  
(457)  
In-line BLOWER-60IL  
In-line BLOWER-110IL  
21" (533)  
18" (457)  
3
20 /4"  
(527)  
10"  
10"  
(254)  
1
(254)  
1
28 /4"  
1
29 /2"  
29 /2"  
(718)  
(749)  
(749)  
10" (254)  
Diameter  
10" (254)  
Diameter  
10" (254)  
Diameter  
1
15 /2"  
(394)  
3
3
14 /4"  
(375)  
14 /4"  
(375)  
1
1
1
29 /2"  
29 /2"  
24 /2"  
(749)  
(749)  
(622)  
3
1
14"  
10 /8"  
10 /8"  
(356)  
(264)  
(257)  
3
4
/4"  
3
(121)  
24 /4"  
(629)  
1
7
1
25"  
22"  
7
/4"  
/4"  
(635)  
(559)  
(184)  
(184)  
Remote BLOWER-60REM and  
BLOWER-90REM  
Remote BLOWER-120REM  
Remote BLOWER-150REM  
Unit dimensions may vary by 1/8" (3).  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
7
 
Planning Information  
Pro 24" (610) Deep Wall Ventilation Hood  
M O D E L P W 6 0 2 4 1 8 ( R )  
P R O V E N T I L A T I O N C F M R E C O M M E N D AT I O N S  
Pro 24" (610) Deep Wall Hoods  
Model  
PW302418 PW362418 PW422418 PW482418 PW542418 PW602418 PW662418  
DF304 / R304 / SRT304  
DF366 / R366 / SRT366 / RT366  
DF364 / R364 / SRT364 / RT364  
RT362  
600  
600  
900  
900  
900  
900  
900  
900  
R488 / RT488  
1100  
1100  
1100  
1100  
1100  
1100  
DF486 / R486 / SRT486 / RT486  
DF484 / R484 / SRT484 / RT484  
DF606 / R606  
1500  
1500  
1500  
1500  
DF604  
Minimum CFM requirements for Wolf ranges and rangetops. CFM recommendations are based on total Btu/hr output.  
Additional CFM may be required for long duct runs.  
P R O V E N T I L A T I O N B L O W E R O P T I O N S  
Pro 24" (610) Deep Wall Hoods  
Blower Description  
600 CFM Internal  
900 CFM Internal  
1200 CFM Internal  
600 CFM In-Line  
1100 CFM In-Line  
600 CFM Remote  
900 CFM Remote  
Blower Number  
Wall Hood Models  
PW302418 / PW362418 / PW422418  
PW302418 / PW362418 / PW422418  
PW482418 / PW542418 / PW602418 / PW662418  
PW302418  
WBLOWER-60INT (810559)  
WBLOWER-90INT (811131)  
WBLOWER-120INT (810316)  
BLOWER-60IL (808331)  
BLOWER-110IL (808332)  
BLOWER-60REM (801640)  
BLOWER-90REM (801641)  
All 24" (610) Deep Wall Hoods  
PW302418  
PW302418 / PW362418 / PW422418  
PW482418 / PW542418  
1200 CFM Remote  
1500 CFM Remote  
BLOWER-120REM (801642)  
BLOWER-150REM (804701)  
All 24" (610) Deep Wall Hoods  
All 24" (610) Deep Wall Hoods  
Dimensions in parentheses are in  
millimeters unless otherwise specified.  
8
 

Whirlpool Cooktop SF111PXSQ2 User Manual
Whirlpool Dishwasher DISHWASHERS User Manual
Whirlpool Garbage Disposal GC1000PE User Manual
Williams Sound Stereo Receiver PPA R751 User Manual
Wolf Ventilation Hood CTEWH36I User Manual
Woods Equipment TV Mount 1013460 User Manual
Xantech Stereo Amplifier MX88 User Manual
Xerox Scanner 665E User Manual
Zanussi Washer Dryer WJD 1667 W User Manual
Zenoah Brush Cutter BC535DLM User Manual